New approach in designing materials for energy conversion and energy storage systems

Link to this page

info:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/172060/RS//

New approach in designing materials for energy conversion and energy storage systems (en)
Нов приступ дизајнирању материјала за конверзију и складиштење енергије (sr)
Nov pristup dizajniranju materijala za konverziju i skladištenje energije (sr_RS)
Authors

Publications

Technetium-99m as a Tracer for the Liquid Residence Time Distribution Measurement: Optimization of Different Radiotracer Parameters for Flow Meter Calibration

Pavlović, Miroslav; Pantović Spajić, Marijana; Bartl, Pavel; Stevanović, Jasmina; Pantović, Radoje; Pantović Spajić, Katarina; Radak, Bojan

(Belgrade : University of Belgrade, Faculty of Mining and Geology, 2019)

TY  - CONF
AU  - Pavlović, Miroslav
AU  - Pantović Spajić, Marijana
AU  - Bartl, Pavel
AU  - Stevanović, Jasmina
AU  - Pantović, Radoje
AU  - Pantović Spajić, Katarina
AU  - Radak, Bojan
PY  - 2019
UR  - https://ritnms.itnms.ac.rs/handle/123456789/1139
AB  - Flow meters are essential part of equipment in almost all chemical and process industries. Knowledge of
the flow dynamics and flow of material through the reactor system is required to evaluate the performance of the
reactors, processes, operation and design. Traditionally this evaluation can be performed using chemical tracers.
Chemical tracer results are not always precise and they could not allow an online diagnosis. The samples
containing chemical tracer have to go to a lab for analysis and chemical tracers are less sensitive than radioactive
ones. Radioactive tracers are the only tracers capable of measuring the active residence time distribution (RTD)
with high degree of precision and give information on-line without stopping the process. In this work the application
of radiotracer method for RTD measurement in flow meter calibration is described. The RTD measurements of the
system were performed in pilot-scale perfect mixer in series reactor for flow meter calibration with Technetium-
99 m (99mTc) as a radiotracer in the form of pertechnetate ion (99mTcO4
-). The optimization of the parameters
included input signal of radiotracer, concentration of radiotracer and position of detectors. The measured data
were analyzed, and standard and relative deviations were quantified under different operating conditions. A plug
flow model was used to simulate the measured RTD curves and investigate the flow dynamics of the flowing water.
The results of the study showed that the optimum concentration of 99mTc for flow meter calibration was 0.3 ml
having activity 0.68 mCi. The standard deviation was σ=0.10 l min-1 and the relative deviation was 0.94%. The
results of the study can help in the operation and design of the existing systems and design of new ones.
PB  - Belgrade : University of Belgrade, Faculty of Mining and Geology
C3  - 7th International Symposium Mining and Environmental Protection, International Conference, Proceedings
T1  - Technetium-99m as a Tracer for the Liquid Residence Time Distribution Measurement: Optimization of Different Radiotracer Parameters for Flow Meter Calibration
EP  - 173
SP  - 166
ER  - 
@conference{
author = "Pavlović, Miroslav and Pantović Spajić, Marijana and Bartl, Pavel and Stevanović, Jasmina and Pantović, Radoje and Pantović Spajić, Katarina and Radak, Bojan",
year = "2019",
abstract = "Flow meters are essential part of equipment in almost all chemical and process industries. Knowledge of
the flow dynamics and flow of material through the reactor system is required to evaluate the performance of the
reactors, processes, operation and design. Traditionally this evaluation can be performed using chemical tracers.
Chemical tracer results are not always precise and they could not allow an online diagnosis. The samples
containing chemical tracer have to go to a lab for analysis and chemical tracers are less sensitive than radioactive
ones. Radioactive tracers are the only tracers capable of measuring the active residence time distribution (RTD)
with high degree of precision and give information on-line without stopping the process. In this work the application
of radiotracer method for RTD measurement in flow meter calibration is described. The RTD measurements of the
system were performed in pilot-scale perfect mixer in series reactor for flow meter calibration with Technetium-
99 m (99mTc) as a radiotracer in the form of pertechnetate ion (99mTcO4
-). The optimization of the parameters
included input signal of radiotracer, concentration of radiotracer and position of detectors. The measured data
were analyzed, and standard and relative deviations were quantified under different operating conditions. A plug
flow model was used to simulate the measured RTD curves and investigate the flow dynamics of the flowing water.
The results of the study showed that the optimum concentration of 99mTc for flow meter calibration was 0.3 ml
having activity 0.68 mCi. The standard deviation was σ=0.10 l min-1 and the relative deviation was 0.94%. The
results of the study can help in the operation and design of the existing systems and design of new ones.",
publisher = "Belgrade : University of Belgrade, Faculty of Mining and Geology",
journal = "7th International Symposium Mining and Environmental Protection, International Conference, Proceedings",
title = "Technetium-99m as a Tracer for the Liquid Residence Time Distribution Measurement: Optimization of Different Radiotracer Parameters for Flow Meter Calibration",
pages = "173-166"
}
Pavlović, M., Pantović Spajić, M., Bartl, P., Stevanović, J., Pantović, R., Pantović Spajić, K.,& Radak, B.. (2019). Technetium-99m as a Tracer for the Liquid Residence Time Distribution Measurement: Optimization of Different Radiotracer Parameters for Flow Meter Calibration. in 7th International Symposium Mining and Environmental Protection, International Conference, Proceedings
Belgrade : University of Belgrade, Faculty of Mining and Geology., 166-173.
Pavlović M, Pantović Spajić M, Bartl P, Stevanović J, Pantović R, Pantović Spajić K, Radak B. Technetium-99m as a Tracer for the Liquid Residence Time Distribution Measurement: Optimization of Different Radiotracer Parameters for Flow Meter Calibration. in 7th International Symposium Mining and Environmental Protection, International Conference, Proceedings. 2019;:166-173..
Pavlović, Miroslav, Pantović Spajić, Marijana, Bartl, Pavel, Stevanović, Jasmina, Pantović, Radoje, Pantović Spajić, Katarina, Radak, Bojan, "Technetium-99m as a Tracer for the Liquid Residence Time Distribution Measurement: Optimization of Different Radiotracer Parameters for Flow Meter Calibration" in 7th International Symposium Mining and Environmental Protection, International Conference, Proceedings (2019):166-173.

In Situ Synthesis of Biocompatible Composite Layer of Hydroxyapatite/Passive Oxide Surfaces on the Modified Titanium

Pantović Pavlović, Marijana; Eraković, Sanja; Pavlović, Miroslav; Pantović Spajić, Katarina; Panić, Vladimir; Pavlović, Miomir

(Bor : University of Belgrade, Technical Faculty in Bor, 2017)

TY  - CONF
AU  - Pantović Pavlović, Marijana
AU  - Eraković, Sanja
AU  - Pavlović, Miroslav
AU  - Pantović Spajić, Katarina
AU  - Panić, Vladimir
AU  - Pavlović, Miomir
PY  - 2017
UR  - https://ritnms.itnms.ac.rs/handle/123456789/1140
AB  - Hydroxyapatite (HAp) is the most suitable biocompatible material for bone implant coatings.
However, its brittleness is a major obstacle, and that is why, recently, research focused on creating composites.
In this study, a novel in situ synthesis of HAp coating on titanium was presented. HAp was anaphoretically
deposited from alkaline-ethanol suspension in one step process. Morphology of the coating was investigated by
optical microscopy, while deposited HAp was characterized using ATR-FTIR. It was concluded that HAp has
excellent coverage of the surface without delamination. The obtained coating can be good material for bone
implants due to solving HAp brittleness.
PB  - Bor : University of Belgrade, Technical Faculty in Bor
C3  - "ECOLOGICAL TRUTH" ECO-IST'17
T1  - In Situ Synthesis of Biocompatible Composite Layer of Hydroxyapatite/Passive Oxide Surfaces on the Modified Titanium
EP  - 306
SP  - 301
ER  - 
@conference{
author = "Pantović Pavlović, Marijana and Eraković, Sanja and Pavlović, Miroslav and Pantović Spajić, Katarina and Panić, Vladimir and Pavlović, Miomir",
year = "2017",
abstract = "Hydroxyapatite (HAp) is the most suitable biocompatible material for bone implant coatings.
However, its brittleness is a major obstacle, and that is why, recently, research focused on creating composites.
In this study, a novel in situ synthesis of HAp coating on titanium was presented. HAp was anaphoretically
deposited from alkaline-ethanol suspension in one step process. Morphology of the coating was investigated by
optical microscopy, while deposited HAp was characterized using ATR-FTIR. It was concluded that HAp has
excellent coverage of the surface without delamination. The obtained coating can be good material for bone
implants due to solving HAp brittleness.",
publisher = "Bor : University of Belgrade, Technical Faculty in Bor",
journal = ""ECOLOGICAL TRUTH" ECO-IST'17",
title = "In Situ Synthesis of Biocompatible Composite Layer of Hydroxyapatite/Passive Oxide Surfaces on the Modified Titanium",
pages = "306-301"
}
Pantović Pavlović, M., Eraković, S., Pavlović, M., Pantović Spajić, K., Panić, V.,& Pavlović, M.. (2017). In Situ Synthesis of Biocompatible Composite Layer of Hydroxyapatite/Passive Oxide Surfaces on the Modified Titanium. in "ECOLOGICAL TRUTH" ECO-IST'17
Bor : University of Belgrade, Technical Faculty in Bor., 301-306.
Pantović Pavlović M, Eraković S, Pavlović M, Pantović Spajić K, Panić V, Pavlović M. In Situ Synthesis of Biocompatible Composite Layer of Hydroxyapatite/Passive Oxide Surfaces on the Modified Titanium. in "ECOLOGICAL TRUTH" ECO-IST'17. 2017;:301-306..
Pantović Pavlović, Marijana, Eraković, Sanja, Pavlović, Miroslav, Pantović Spajić, Katarina, Panić, Vladimir, Pavlović, Miomir, "In Situ Synthesis of Biocompatible Composite Layer of Hydroxyapatite/Passive Oxide Surfaces on the Modified Titanium" in "ECOLOGICAL TRUTH" ECO-IST'17 (2017):301-306.

Potentiostatic oxidation of AgCu50 alloy in alkaline solution in the presence of chlorides

Rajcić-Vujasinović, Mirjana; Grekulović, Vesna; Stević, Zoran; Vuković, Nikola

(Pergamon-Elsevier Science Ltd, Oxford, 2013)

TY  - JOUR
AU  - Rajcić-Vujasinović, Mirjana
AU  - Grekulović, Vesna
AU  - Stević, Zoran
AU  - Vuković, Nikola
PY  - 2013
UR  - https://ritnms.itnms.ac.rs/handle/123456789/263
AB  - SEM and EDS analyses of AgCu50 alloy were performed after potentiostatic oxidation in an alkaline solution in the presence or absence of chloride ions. Oxidation in pure alkaline solution was favoured on the portion where a eutectic mixture was present on the surface. There was an essential difference between SEM images obtained in pure alkaline solution and in the presence of chloride, when voluminous deposits covering the whole eutectic area and expanding towards the middle of primary crystals appeared. EDS analysis confirmed that both oxides and chlorides of silver form in parallel. Chlorides disturb the protective performance of copper oxides.
PB  - Pergamon-Elsevier Science Ltd, Oxford
T2  - Corrosion Science
T1  - Potentiostatic oxidation of AgCu50 alloy in alkaline solution in the presence of chlorides
EP  - 228
SP  - 221
VL  - 70
DO  - 10.1016/j.corsci.2013.01.033
UR  - conv_652
ER  - 
@article{
author = "Rajcić-Vujasinović, Mirjana and Grekulović, Vesna and Stević, Zoran and Vuković, Nikola",
year = "2013",
abstract = "SEM and EDS analyses of AgCu50 alloy were performed after potentiostatic oxidation in an alkaline solution in the presence or absence of chloride ions. Oxidation in pure alkaline solution was favoured on the portion where a eutectic mixture was present on the surface. There was an essential difference between SEM images obtained in pure alkaline solution and in the presence of chloride, when voluminous deposits covering the whole eutectic area and expanding towards the middle of primary crystals appeared. EDS analysis confirmed that both oxides and chlorides of silver form in parallel. Chlorides disturb the protective performance of copper oxides.",
publisher = "Pergamon-Elsevier Science Ltd, Oxford",
journal = "Corrosion Science",
title = "Potentiostatic oxidation of AgCu50 alloy in alkaline solution in the presence of chlorides",
pages = "228-221",
volume = "70",
doi = "10.1016/j.corsci.2013.01.033",
url = "conv_652"
}
Rajcić-Vujasinović, M., Grekulović, V., Stević, Z.,& Vuković, N.. (2013). Potentiostatic oxidation of AgCu50 alloy in alkaline solution in the presence of chlorides. in Corrosion Science
Pergamon-Elsevier Science Ltd, Oxford., 70, 221-228.
https://doi.org/10.1016/j.corsci.2013.01.033
conv_652
Rajcić-Vujasinović M, Grekulović V, Stević Z, Vuković N. Potentiostatic oxidation of AgCu50 alloy in alkaline solution in the presence of chlorides. in Corrosion Science. 2013;70:221-228.
doi:10.1016/j.corsci.2013.01.033
conv_652 .
Rajcić-Vujasinović, Mirjana, Grekulović, Vesna, Stević, Zoran, Vuković, Nikola, "Potentiostatic oxidation of AgCu50 alloy in alkaline solution in the presence of chlorides" in Corrosion Science, 70 (2013):221-228,
https://doi.org/10.1016/j.corsci.2013.01.033 .,
conv_652 .
3
3
4